When the air conditioner is cooling, why does the air outlet drip?

  • Categories:NEWS
  • Author:
  • Origin:
  • Time of issue:2020-09-29 18:24
  • Views:

(Summary description)How does air conditioning condensate form? This is because the water vapor in the air meets the evaporator with low temperature and liquefies into condensate. Generally, the condensate water will flow down from the evaporator, and then continue to flow down to the condensation pipe through the water collecting pan, and then flow to the outdoor through the pipe. It should be noted that the discharge of condensate depends on gravity, which makes the water flow down automatically and flows out of the outdoor.

When the air conditioner is cooling, why does the air outlet drip?

(Summary description)How does air conditioning condensate form? This is because the water vapor in the air meets the evaporator with low temperature and liquefies into condensate. Generally, the condensate water will flow down from the evaporator, and then continue to flow down to the condensation pipe through the water collecting pan, and then flow to the outdoor through the pipe. It should be noted that the discharge of condensate depends on gravity, which makes the water flow down automatically and flows out of the outdoor.

  • Categories:NEWS
  • Author:
  • Origin:
  • Time of issue:2020-09-29 18:24
  • Views:
Information

How does air conditioning condensate form? This is because the water vapor in the air meets the evaporator with low temperature and liquefies into condensate.

But if something goes wrong with these links. It will lead to condensation water can not flow to the outdoor, which will lead to indoor air conditioning outlet dripping. So, what are the causes?

1. The water collecting pan is damaged

     If the water collecting plate is broken, the water drops directly onto the water collecting plate, which will naturally cause water dripping in the air conditioner.

2. Uneven water collecting pan

    If the air conditioner is not installed properly, it will lead to uneven hanging of the air conditioner. Therefore, if the collecting tray is uneven, one side is high and the other side is low, which will cause the lower side to overflow.

3. The water collecting pan is too low

    The reason why the condensate can be discharged to the outdoor is completely dependent on Gravity - the water can only go down under the gravity, so if the height of the water collecting tray is lower than that of the condensate pipe, the water will not be discharged.

4. Condensation tube blocked

    The condensate enters the water collecting tray, but there is no access to the outside. Slowly, the water in the water tray is full, and it will overflow, causing the internal machine to drip.

5. The condenser tube is damaged

    After all, there is a thin layer of plastic leakage out of the pipe.

     If the condenser pipe is not long enough and a section of pipe is added, the joint may also leak water - the condenser pipe joint can not be sealed, that is, two plastic pipes are inserted together, which is very unstable.

6. The evaporator is too dirty

    If the upper part of the evaporator is too dirty, it may block the path of condensate flow, so that the condensate does not flow down, but flows away from both sides. This will cause the indoor unit to drip.

Keyword:

Scan the QR code to read on your phone

Online customer service
Customer service hotline
Service time:
-
Customer service group:
在线客服
Skype:
QQ:

CONTACT

Tel : (86)757-87575702
Fax: 0757-87655136
E-mail:
dengxiaoshun@fstb.com.cn

           87616064@qq.com
Address: No.41,HuiJin Rd.,Baini Town 
Sanshui District,Foshan,Guangdong,China

Username used for comment:
Customer message
Description:

Copyright © 2018  FOSHAN TONGBAO Co., Ltd. | All Rights Reserved.  粤ICP备18141955号-1     Powered By:300.cn

Customer message